    Description

    Untitled Document
    Fluke 435-II Power Quality and Energy Analyzer
    Model:
    435-II
    | Order No:
    435-II
    Capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics with this power quality and energy analyzer. Quickly understand the capacity of your existing electrical panels, troubleshoot circuit breaker trips and uncover and monetize energy costs.
    Brand:
    Fluke
    Model:
    435-II
    Order No:
    435-II
    Condition:
    NEW
    Description
    Fluke 435-II Power Quality and Energy Analyzer
    Fluke 435-II Offers
    Advanced power quality functions, unprecedented energy analysis capabilities
    Power quality issues may affect the operation of critical loads and impact on your bottom line negatively. Think of this power quality and energy analyzer as an insurance policy. The user can calculate the cost of wasted energy due to poor power quality, and troubleshoot the source of power quality or motor performance issues. Additionally, it's designed to provide the user with the data needed to quickly get to the root of the problem.
    Quickly see how much money you're losing due to energy waste in terms of real dollars
    Easily see how motor startups are affecting motor drive performance
    Get at-a-glance power quality health data in real-time so you can make better maintenance decisions
    Capture every measurement automatically without any set-up so you don't have to worry about not having the right data
    Measure all three phases and neutral with the included flexible current probes
    * View data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software
    Features
    Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available)
    Power inverter efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp
    PowerWave data capture: Captures fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.)
    Waveform capture: Captures 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up
    Automatic Transient Mode: Captures 200 kHz waveform data on all phases simultaneously up to 6 kV
    Fully Class-A compliant: Conducts tests according to the stringent international IEC 61000-4-30 Class-A standard
    Mains signaling: Measures interference from ripple control signals at specific frequencies
    Troubleshoot: Analyze the trends using the cursors and zoom tools
    Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance
    Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex designed to fit into the tightest places
    Automatic Trending: Every measurement is always automatically recorded, without any set-up
    System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard
    Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals
    View graphs and generate reports: With included analysis software
    Battery life: Up to 8 hours operating time per charge on Li-ion battery pack
    Wireless data download: Download data to PC wirelessly and capture screens using Fluke Connect App
    Measure multiple parameters simultaneously to quickly understand overall power quality health
    View data as simple digital values or more detailed trend graphs that give you fast insight into changes over time, waveforms, and phasor diagrams
    Organize data in tabular format so you can quickly correlate parameters like magnitude, duration, and time to the issues you are experiencing in your facility
    Applications
    Frontline troubleshooting: Quickly diagnose problems on-screen to get your operation back online
    Long-term analysis: Uncover hard-to-find or intermittent issues
    Load studies: Verify the available electrical system capacity before adding loads
    PowerWave data capture: Capture every waveform for up to 5 minutes along with fast RMS values so you can determine how the voltage, current and frequency values are interacting
    Power inverter efficiency: Measure the input and output power simultaneously to discover whether the inverter is optimized for its application
    Energy monetization: Calculate the fiscal cost of energy waste due to poor power quality
    Energy assessment: Quantify the before and after installation improvements in energy consumption to justify energy saving devices
    Predictive maintenance: Periodic benchmarking of the power system can help detect and prevent power quality issues before they cause downtime
    Energy savings
    Traditionally energy savings are achieved by monitoring and targeting, or in other words, by finding the major loads in a facility and optimizing their operation. The cost of power quality could only be quantified in terms of downtime caused by lostproduction and damage to electrical equipment. The unified power measurement (UPM) method now goes beyond this to achieve energy savings by discovering the energy waste caused by power quality issues. Using the unified power measurement, the energy loss calculator will determine how much money a facility is losing due to waste energy.
    Unbalance
    UPM gives a more comprehensive breakdown of the energy consumed in the plant. In addition to measuring reactive power (caused by poor power factor), UPM also measures the energy waste caused by unbalance; the effect of unevenly loading each phase in three-phase systems. Unbalance can often be corrected by reconnecting loads on different phases to ensure the current drawn on each phase is as equal as possible. Unbalance can also be corrected by installing an unbalance reactance device (or filter), that will minimize the effects. Correcting unbalance should be basic good housekeeping in the facility as unbalance problems can cause motor failure or shorten equipment life expectancy. Unbalance also wastes energy. Using UPM can minimize or eliminate that energy waste.
    Harmonics
    UPM also provides details of the energy wasted in your facility due to the presence of harmonics. Harmonics may be present in your facility due to the loads you operate or may be caused by loads in adjacent facilities. The presence of harmonics inyour facility can lead to:
    Overheating transformers and conductors
    Nuisance tripping of circuit breakers
    Early failures of electrical equipment
    Quantifying the cost of wasted energy due to the presence of harmonics simplifies the return-oninvestment calculation needed to justify purchasing harmonic filters. By installing a harmonic filter the ill effects of harmonics can be reduced and energy waste eliminated, resulting in lower operational costs and more reliable operation.
    Energy loss calculator - calculate money lost to energy waste in terms of real dollars
    It's a simple fact, poor power quality can have a big impact on the bottom line. This power quality analyzer enables you to identify issues and measure energy loss giving you specific insight into the amount of loss in dollars associated with things like effective power and with poor power quality characteristics such as reactive power, unbalance, distortion, or neutral current. The power anlayzer even offers users the flexibility to input cable length and cable diameter so you can calculate loss due to conductor sizing (Or use AUTO mode if you don't know your cable specification) and enter up to four unique time-dependent daily rates (kWh) for more accurate calculations. Armed with this critical data users can easily justify the investment necessary to take countermeasures.
    Powerful troubleshooting capabilities
    Specifically designed with the needs maintenance engineers and technicians in mind; users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime. The measurement process and display of data is optimized to get to the most important information as quickly as possible. Multiple parameters are measured simultaneously and displayed in formats that quickly describe the state of the power quality of the system. Data can be quickly accessed as simple digital values, trend graphs, waveforms, phasor diagrams or analyzed and organized into tabular format such as the event data where the magnitude, duration and time stamping enable rapid correlation to problems experienced.
    AutoTrend - Quickly see the trend
    Unique autotrend gives you fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or having to manually start the process. You can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.
    The system - monitor overview screen
    Instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. A detailed list is given of all events falling outside the set limits.
    PowerWave data capture
    For some users, load switching is a cause of power quality problems. When loads switch on, the current draw sometimes causes the voltage to drop to a level that causes other equipment to malfunction. The PowerWave function a enables users to capture voltage, current and frequency signals simultaneously at a high speed to see which interaction is potentially causing problems. PowerWave goes beyond standard power quality measurements; PowerWave's fast data capture mode enables system dynamics to be characterized.
    Waveforms for voltage and current are continuously captured for the specified time, and are displayed on screen in high detail; the power waveform is derived from the data. In addition, half-cycle RMS values for voltage, current, power and frequency can be stored and retrieved for analysis. This feature is particularly useful for testing of standby generation systems and UPS systems where reliable switch-on can be vital.
    PowerWave data capture - quickly identify how motor and generator startups are impacting equipment performance
    With PowerWave data capture you can capture three-phase high resolution voltage and current waveforms for up to five minutes along with detailed RMS voltage and current values. By analyzing the interaction of these values over time you can correlate the effects of voltage, current and frequency during the critical startup of motors and generators. PowerWave even goes beyond the standard power quality measurements allowing you to record half cycle rms values on 8 channels, frequency and instantaneous power (Vrms1/2, Arms1/2, W, Hz and scope waveforms for voltage, amps and watts).
    Advanced power quality health
    Advanced power quality health - at-a-glance power quality health data in real-time so you have the data you need, when you need it
    This power analyzer utilize an integrated power quality health summary that gives you an at-a-glance view of a complete range of power quality issues in real time. With a simple graphical presentation, complete with tolerance limits, you can quickly discover which power quality problems may be present on your electrical system. If you don't know where to start or what problems might exist the advanced power quality health summary will simplify the task.
    Power inverter efficiency
    Power inverters take DC current and transform it into AC current, or vice versa. Solar generation systems usually include an inverter that takes the DC energy from the solar cells and converts it to useful AC power. Inverters can lose performance over time and need to be checked. By comparing the input power with the output power you can determine the system efficiency. This energy analyzer can measure the efficiency of such inverters by simultaneously measuring the DC and AC power of a system to determine how much power is lost in the conversion process.
    With a unique autotrend feature you can get fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or having to manually start the process So you can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.
    Unified power measurement
    Previously, only experts could calculate how much energy was wasted due to power quality issues; utilities could calculate the cost, but the required measurement process was beyond the reach of average electricians. With this patented unified power function you can use one handheld tool to determine how much power is being wasted, and calculate exactly what the extra consumption costs.
    The patented unified power measurement system provides the most comprehensive view of power available, measuring:
    Parameters of classical power (Steinmetz 1897) and IEEE 1459-2000
    Detailed loss analysis
    Unbalance analysis
    These UPM calculations are used to quantify the fiscal cost of energy loss caused by power quality issues. The calculations are computed, along with other facility-specific information by an Energy Loss Calculator that ultimately determines how much money a facility loses due to wasted energy.
    SystemMonitor - check performance against EN50160 with ease
    The unique system-monitor gives you an overview of power system performance (there is no button or single function) and checks the compliance of incoming power to EN50160 limits or to your own custom specifications. The overview is shown on a single screen, with color-coded bars clearly indicating which parameters fall outside the limits.
    Logging function allows you to customize measurement selections and provides instantaneous analysis of user-selectable parameters.
    Measure and record power (W), VA and VARs, PF and energy consumption.
    Track harmonics up to the 50th, and measure and record THD in accordance with IEC61000-4-7 requirements.
    Included
    Power Quality and Energy Analyzer
    4 x 24" (61 cm) Flexible Current Probes
    Test Lead & Alligator Clip Set
    Clips and Regional Decals
    8 GB SD Card
    USB Cable
    Carrying Case
    Power Adapter
    International Plug Adapter Set
    Single Capacity 28 Wh Li-Ion Battery
    PowerLog on CD (Includes Operator Manuals in PDF Format)
    Specifications
    Volt
    Vrms (AC + DC)
    Measurement range: 1 to 1000 V phase to neutral
    Resolution: 0.01 V
    Accuracy: ±0.1% of nominal voltage
    1
    Vpk
    Measurement range: 1 to 1400 Vpk
    Resolution: 1 V
    Accuracy: 5% of nominal voltage
    Voltage Crest Factor (CF)
    Measurement range: 1.0 > 2.8
    Resolution 0.01
    Accuracy: ±5%
    Vrms
    1/2
    Resolution: 0.1 V
    Accuracy: ±0.2% of nominal voltage
    Amps
    i430-Flex 1x
    Measurement range: 5 to 6000 A
    Resolution: 1 A
    Accuracy: ±0.5% ±5 counts
    i430-Flex 10x
    Measurement range: 0.5 to 600 A
    Resolution: 0.1 A
    Accuracy: ±0.5% ±5 counts
    1mV/A 1x
    Measurement range: 5 to 2000 A
    Resolution: 1 A
    Accuracy: ±0.5% ±5 counts
    1mV/A 10x
    Measurement range: 0.5 to 200 A (AC only)
    Resolution: 0.1 A
    Accuracy: ±0.5% ±5 counts
    i430-Flex
    Measurement range: 8400 Apk
    Resolution: 1 Arms
    Accuracy: ±5%
    1mV/A
    Measurement range: 5500 Apk
    Resolution: 1 Arms
    Accuracy: ±5%
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.