-40%

Fluke 725US-NIST Multifunction Process Calibrator,

$ 1832.15

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • All returns accepted: Returns Accepted
  • Brand: Fluke
  • Condition: New
  • MPN: 725US-NIST
  • Return shipping will be paid by: Seller
  • Item must be returned within: 30 Days

    Description

    Untitled Document
    Fluke 725US-NIST Multifunction Process Calibrator,
    Model:
    725US-NIST
    | Order No:
    725US-NIST
    Easily source and measure a wide variety of process parameters and test many process devices. This unit is capable of measuring and sourcing mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules.
    Brand:
    Fluke
    Model:
    725US-NIST
    Order No:
    725US-NIST
    Condition:
    NEW
    Description
    Fluke 725US-NIST Multifunction Process Calibrator,
    Format->drawDescription($name, $product ); ?>
    Features
    Powerful, easy-to-use field calibrator
    Measures volts, mA, pressure, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters
    Sources/simulates volts dc, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
    Measures/sources pressure using any of 50 750P Pressure Modules (sold separately)
    Easy to read measure/source screen displays input and output simultaneously
    Powers transmitters during test using loop supply with simultaneous mA measurement
    Handles fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms
    Provides a backlit display to provide better visibility in poor light
    Features small, streamlined shape, and rugged, reliable design that stands up to field use
    Sources mA with simultaneous pressure measurement to conduct valve and I/P tests
    Supports flow meter testing with frequency and CPM functions
    Performs fast linearity tests with auto-step and auto-ramp features
    Included
    Process Calibrator
    Format->drawIncluded($name, $product ); ?>
    Test Leads
    Test Clips
    Stackable Test Leads
    Users Manuals
    Statement of Quality Assurance Practices
    CE and CSA Markings
    Specifications
    Measurement Accuracy
    Voltage DC
    30.000 V: 0.02% + 2 counts (upper display)
    30.000 V: 0.02% + 2 counts (lower display)
    100.00 mV: 0.02% + 2 counts
    -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
    Current DC
    24.000 mA: 0.02% + 2 counts
    Resistance
    0.0 to 400.0 &ohm: 0.1 &ohm (4-wire), 0.15 &ohm (2- and 3-wire)
    401 to 1500 &ohm: 0.5 &ohm (4-wire), 1 &ohm (2- and 3-wire)
    1500 to 3200 &ohm: 1 &ohm (4-wire), 1.5 &ohm (2- and 3-wire)
    Frequency
    2.0 to 1000.0 CPM: 0.05% + 1 count
    1.0 to 1100.0 Hz: 0.05% + 1 count
    1.00 to 10.00 kHz: 0.05% + 1 count
    Sensitivity: 1 V peak-to-peak-minimum
    Pressure
    Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
    Source Accuracy
    Voltage DC
    100.00 mV: 0.02% + 2 counts
    10.000 V: 0.02% + 2 counts
    -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
    Current DC
    24.000 mA (source): 0.02% + 2 counts
    24.000 mA (simulate): 0.02% + 2 counts
    Resistance
    15.0 to 400.0 &ohm: 0.15 &ohm (exc. current 0.15 to 0.5 mA), 0.1 &ohm (exc. current 0.5 to 2 mA)
    401 to 1500 &ohm: 0.5 &ohm (excitation current 0.05 to 0.8 mA)
    1500 to 3200 &ohm: 1 &ohm (excitation current 0.05 to 0.4 mA)
    Frequency
    2.0 to 1000.0 CPM: 0.05%
    1.0 to 1100.0 Hz: 0.05%
    1.00 to 10.00 kHz: 0.25%
    Waveform: 5 V p-p squarewave, -0.1 V offset
    RTDs and Thermocouples
    Measure Accuracy
    NI-120: 32.36°F (0.2°C)
    PT-100 (385): 32.6°F (0.33°C)
    PT-100 (393): 32.54°F (0.3°C)
    PT-100 (JIS): 32.54°F (0.3°C)
    PT-200 (385): 32.36°F (0.2°C)
    PT-500 (385): 32.54°F (0.3°C)
    PT-1000 (385): 32.36°F (0.2°C)
    Resolution: 0.1°C
    J: 33.26°F (0.7°C)
    K: 33.44°F (0.8°C)
    T: 33.44°F (0.8°C)
    E: 33.26°F (0.7°C)
    R: 35.24°F (1.8°C)
    S: 34.7°F (1.5°C)
    B: 34.52°F (1.4°C)
    L: 33.26°F (0.7°C)
    U: 33.35°F (0.75°C)
    N: 33.62°F (0.9°C)
    Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
    XK: 33.08°F (0.6°C)
    BP: 34.16°F (1.2°C)
    Source Accuracy
    NI-120: 32.36°F (0.2°C)
    PT-100 (385): 32.6°F (0.33°C)
    PT-100 (393): 32.54°F (0.3°C)
    PT-100 (JIS): 32.54°F (0.3°C)
    PT-200 (385): 32.36°F (0.2°C)
    PT-500 (385): 32.54°F (0.3°C)
    PT-1000 (385): 32.36°F (0.2°C)
    Resolution: 0.1°C
    Accuracy stated for 4-wire measurement
    J: 33.26°F (0.7°C)
    K: 33.44°F (0.8°C)
    T: 33.44°F (0.8°C)
    E: 33.26°F (0.7°C)
    R: 34.52°F (1.4°C)
    S: 34.7°F (1.5°C)
    B: 34.52°F (1.4°C)
    L: 33.26°F (0.7°C)
    U: 33.35°F (0.75°C)
    N: 33.62°F (0.9°C)
    Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
    XK: 33.08°F (0.6°C)
    BP: 34.16°F (1.2°C)
    Functions Specifications
    Ramp Functions
    Source functions: Voltage, current, resistance, frequency, temperature
    Ramps: Slow ramp, Fast ramp, 25% step-ramp
    Loop Power Function
    Voltage: 24 V
    Accuracy: 10%
    Maximum current: 22 mA, short circuit protected
    Step Functions
    Source functions: Voltage, current, resistance, frequency, temperature
    Steps: 25% of range, 100% of range
    Environmental Specifications
    Operating Temperature
    14 to 131°F (-10 to 55°C)
    Storage Temperature
    -4 to 159.8°F (-20 to 71°C)
    Operating Altitude
    9842.52' (3000 m)
    Mechanical and General Specifications
    Batteries
    4 x AA alkaline batteries
    Battery Replacement
    Separate battery compartment, accessable without breaking calibration seal
    Side Port Connections
    Pressure module connector, also used for remote real-time programming
    Dimensions
    5.1 x 9.3 x 2.4" (130 x 236 x 61 mm)
    Weight
    1.43 lbs (0.65 kg)
    Safety Specifications
    Agency Approvals
    EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.