-40%

Loop Process tester VOLT/mA CALIBRATOR MS7221 MASTECH Step DC Volts,current

$ 194.62

Availability: 99 in stock
  • Brand: MASTECH
  • Refund will be given as: Money Back
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Model: MS7221
  • Item must be returned within: 30 Days
  • Country/Region of Manufacture: China
  • Condition: New
  • MPN: MS7221

    Description

    Loop Process tester VOLT/mA CALIBRATOR MS7221 MASTECH
    Description
    NEW MASTECH MS7221 multi-function VOLT/mA CALIBRATOR
    Source/Output Step
    DC Volts, current, Frequency
    and measure
    Volts Amps Resistance Frequency, Temperture
    , can connect to RS232
    Brand new with 1 year USA warranty + 14 days return policy
    FEATURES
    1.Measurement V, mA, Frequency, Ω, Temperature, max count 40000.
    2.Source output of voltage, current, frequency with high accuracy, voltage and current can increase by degrees in  0 to 99 steps to output step voltage and step current.
    3.With PC photoelectricity interface and PC windows software to record data and export graph.
    4.With measurement function and source output function, double display to show and control.
    5.With 32 function button and numeric button,Source output can be set and modified directly by numeric button.
    6.Output Power:15V 25mA
    MS7221 Volt/mA Calibrator is a source and measurement tool. This Calibrator can be used in measurement or output 0 to 24 mA DC current loop, and 0 to 10 V DC voltage.

    Display: 40000 counts

    Measure loop current signals with very high accuracy of 0.015% and 1 uA resolution

    Measure voltage output process signals from PLCs, transmitters

    Source or simulate 24 mA loop current

    Source voltage to 100 mV or 10V

    24V loop supply with simultaneous current measurement
    SPECIFICATIONS
    DCV Measure:
    0 ~ 100m V, 0 ~ 10 V±0.02%
    DCV Source:
    0 ~ 100m V, 0 ~ 10 V±0.02%
    DCmA Measure(% of span):
    0 ~ 24 mA±0.015%
    DCmA Source(% of span):
    0 ~ 24 mA±0.015%
    Weight:
    350g (include battery)
    Size:
    190mm × 89mm × 42mm
    Battery:
    9VDC,006P or 1604
    Specifications
    General Specification
    •Display : Max 40000
    •Range: autorange
    •Overload indication: “OL” on the LCD
    •Reading Holding:    on the LCD
    •Power Supply: AA 1.5Vx 8 piece and 9V Alkaline type one piece
    •Storage Temperature: -20℃~70℃
    •Operating Temperature: 0℃~40℃
    •Safety: Designed to ICE1010_1 300V CAT.Ⅲ
    •Dimension Size : 224mm×172mm×59mm
    •Weight : approx. 1100g (include batteries

    RS232 Data Interface
    The instrument can transmit data to PC computer by a RS232 infrared photoelectricity interface in real-time mode. You can connect the RS232 interface to a serial port of PC computer, then install the user data record software into the computer according to the README.TEXT file in the SETUP disk. After that, you can record and print the measured data of the instrument in real-time mode on the WINDOWS. The user data record special software can complete to record, collate, plot, print data in real-time mode.
    Note: In all measurement mode, the measured data can be transmitted to the PC serial port automatically, but the
    instrument will stop transmitting in the SETUP mode.
    Backlight
    Low Voltage Indication
    Accuracy and Resolution
    Accuracy is given as ±(% of reading +number of least significant digits)at 18℃ to 28℃,with humidity up to 80%
    Measurement·DC Volts
    RANGE
    ACCURACY
    RESOLUTION
    400.00 mV
    0.025%rdg+10d
    0.01mV
    4.0000 V
    0.025%rdg+5d
    0.1mV
    40.000V
    0.025%rdg+5d
    1mV
    300.00V
    0.025%rdg+5d
    10mV
    Max Overload Voltage: 400V (RMS)
    Measurement·AC Volts
    RMS
    RANGE
    ACCURACY
    RESOLUTION
    400.00mV
    0.7%rdg+20d
    0.01mV
    4.0000V
    0.7%rdg+10d
    0.1mV
    40.000V
    0.7%rdg+10d
    1mV
    300.00V
    0.7%rdg+10d
    10mV
    Max Overload Voltage: 400V (RMS)
    Measurement·DC Current
    RANGE
    ACCURACY
    RESOLUTION
    400.00mA
    0.1%rdg+10d
    0.01mA
    Overload Protection: 500mA/250V Fuse
    Measurement·AC Current                            RMS
    RANGE
    ACCURACY
    RESOLUTION
    400.00mA
    0.7%rdg+10d
    0.01mA
    Overload Protection: 500mA/250V Fuse
    Measurement·Resistance
    RANGE
    ACCURACY
    RESOLUTION
    400.00Ω
    0.1%rdg+10d
    0.01Ω
    4.0000kΩ
    0.1%rdg+10d
    0.1Ω
    40.000 kΩ
    0.1%rdg+10d

    400.00 kΩ
    0.1%rdg+10d
    10Ω
    Max Overload Voltage: 250V (RMS)
    Measurement·Frequency
    RANGE
    ACCURACY
    RESOLUTION
    4Hz~999.9Hz
    0.05
    0.01Hz
    100Hz ~5kHz
    0.5Hz
    0.01Hz~0.1Hz
    5kHz ~30kHz
    2Hz
    0.1Hz~1Hz
    Min Measurement Voltage: 50mV
    Max Overload Voltage: 400V (RMS)
    Measurement·Temperature
    RANGE
    ACCURACY
    RESOLUTION
    -50℃~1300℃
    ±0.3%+1℃
    0.1℃
    Source·Voltage
    RANGE
    ACCURACY
    RESOLUTION
    100.000mV DC
    0.025%+0.03%
    1μV
    5.0000V DC
    0.025%+0.02%
    100μV
    15.000V DC
    0.025%+0.02%
    1mV
    Step time: 1~99       Step Cycle: 1~99s
    Accuracy is given as ±(% of reading +% of range)
    Source·Current
    RANGE
    ACCURACY
    RESOLUTION
    25.000mA
    0.02%+0.02%
    1μA
    Accuracy is given as ±(% of reading +% of range)
    Source·Frequency
    RANGE
    ACCURACY
    RESOLUTION
    20Hz~5000Hz
    0.02%
    0.01Hz~0.1Hz
    18 standard frequency: 5kHz, 2500Hz, 2000Hz, 1250Hz, 1000Hz, 800Hz, 500Hz, 400Hz, 250Hz,
    200Hz, 160Hz, 100Hz, 80Hz, 60Hz, 50Hz, 40Hz, 25Hz, 20Hz。
    Shipping: USA order will ship from our USA warehouse, ALL ither orders will ship from our China warehouse by air mail with track number, it takes around 8-14 business days to arrive, thank you
    Accessories
    •  Red/black banana test leads;
    • Hard carrying case;