-40%

ONE YHS726 Multifunctional process calibrator with pressure measuring function

$ 396

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • All returns accepted: Returns Accepted
  • Brand: Unbranded/Generic
  • Item must be returned within: 60 Days
  • Restocking Fee: No
  • Model: YHS-726
  • Condition: New
  • MPN: Does Not Apply
  • UPC: Does Not Apply
  • Return shipping will be paid by: Buyer

    Description

    Complicit Components
    ONE YHS726 Multifunctional process calibrator with pressure measuring function
    Introduction:
    The YHS726 Multifunction Process Calibrator is a powerful, yet easy-to-use field calibrator. Use the measure and source functions to test and calibrate almost any process parameter.
    Small, streamlined shape makes it easy to carry.
    Rugged, reliable design stands up to field use.
    Easy to read measure/source screen lets you view input and output simultaneously.
    Measure volts, mA, RTDs, thermocouples and ohms to test sensors and transmitters.
    Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters.
    Support flow meter testing with frequency and CPM functions.
    Perform fast linearity tests with auto- step and auto-ramp features.
    Power transmitters during test using loop supply with simultaneous mA measurement.
    Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms *Store frequently used test setups for later use.
    Backlight lets you work in poor light.
    Large battery capacity of four AA cells.
    Battery door for easy changes.
    Feature:
    A split-screen display. The upper display allows users to measure volts, current, and only. The lower display allows the user to measure and source volts, current, resistance temperature detectors, thermocouples and ohms.
    A thermocouple (TC) input/output terminal with cold junction temperature compensation, ambient temperature can be set and calibrate within the menu function.
    Each parameters can manual and automatic stepping and ramping output, signal output can be arbitrarily set within the 0%,25% and 100% of the value.
    In the configuration menu can be set manually : Power off time for Instrument Backlight off time Screen Contrast Cold junction compensation ON/OFFHART resistence ON/OFF and ETC.
    Have calendar clock function, it can be calibrated in configuration menu.
    It can be store 8 sets of measurement and output data and call the showing at any time, all the settings and the functions of the last operation be auto-stored after power off.
    High capacity rechargeable battery pack, with power adapter, within integrated charge-management functions.
    Novel shape, large screen dot-matrix graphic display, can display Chinese characters, digital key to input personalized , make the operation more simple.
    2.Specificatoin:
    Function
    YHS-724
    YHS-726
    Measurement Function
    Upper Screen
    DC Voltage
    0.000~30.000V
    0.000~30.000V
    DC Current
    0.000~24.000mA
    0.000~24.000mA
    Loop power
    0.000~24.000mA
    0.000~24.000mA
    Under Screen
    DC V
    0~24.000V
    0~20.000V
    DC mA
    0-24.000mA
    0-24.000mA
    Resistance
    0Ω~ 4000.0Ω
    0Ω~ 4000.0Ω
    Frequency
    0.01~ 99.99Hz,
    1.00~ 15.00KHz
    Sensitivity
    200mV peak value ~peak valu
    Pressure
    Include 40 kinds of pressure module, range:
    0 ~70Mpa,   the type include: Gage Pressure, Differential Pressure, Absolute Pressure, Compound  Pressure and Vacuum Pressure.
    Thermocouple (TC)
    Type: S, R, B, K, N, E, J, T,(mV)
    Resistance-Temperature Detector (RTD)
    Pt100(385) Pt100(3926) Pt100(3916) Pt200(385)
    Pt500(385)  Pt1000(385) Cu100(ITS) Cu50(ITS)
    Output Function
    DCV
    0.000~20.000V
    DC mV
    0.000~90.000mV
    DC Current
    0.000~24.000mA
    Resistance
    15.0Ω~ 4000.0Ω
    Frequency
    0.01~ 99.99Hz,
    1.00~ 15.00KHz
    Wave shape
    Square wave, -0.1V gap, range can adjust(0 ~20V), Duty cycle can adjust (0.3~ 99.7%)
    Thermocouple (TC)
    Type: S, R, B, K, N, E, J, T,(mV)
    Resistance-Temperature Detector (RTD)
    Pt100(385) Pt100(3926) Pt100(3916) Pt200(385)
    Pt500(385)  Pt1000(385) Cu100(ITS) Cu50(ITS)
    Other functions
    Stepping output, Ramping output, Store data A split-screen display.
    Measure Accuracy.
    Function
    Measure Singal
    Measure  Accuracy
    Output
    DC Voltage
    0.000~30.000 V
    0.02%+3 counts  (The upper display)
    0.000~24.000 V
    0.02%+ 3 counts (The lower display)
    0.000~90.000 mV
    0.01%+ 10 counts
    -10.000~80.000mV 0.01 % + 10 counts (use the thermocouple jack )
    DC Current
    0.000~24.000 mA
    0.02%+ 4 counts(The upper display)
    0.000~24.000 mA
    0.02%+ 4 counts(The lower display)
    Resistance
    0.00~400.00Ω
    0.1Ω (4 wire), 0.15Ω (2 wire and 3 wire)
    400.0~4000.0Ω
    0.5Ω (4 wire), 1Ω (2 wire and 3 wire)
    Output Accuracy.
    Output
    Range
    Accuracy
    DC Voltage
    0.000 ~20.000 V
    0.02%+3 counts
    0.000~90.000 m V
    0.01%+10 counts
    -10.000 mV~80.000 mV   0.01 % + 10 counts (use the thermocouple jack )
    DC Current
    0.000~24.000 mA
    0.02%+ 4 counts
    Resistance
    5.00~400.00 Ω
    0.15 Ω (Excitation current 0.15 to 0.5 mA),
    0.1Ω (Excitation current 0.5 to 2 mA)
    400.0~4000.0 Ω
    0.5Ω(Excitation current 0.05 to 0.8 mA)
    Thermocouple specification.
    Type
    Positive Lead
    Material
    Positive Lead (H)Color
    Negative Lead
    Material
    Specified Range
    (°C)
    ANSI*
    IEC**
    S
    Platinum (10 % Rhodium)
    Black
    Orange
    Platinum
    -50-1760
    R
    Platinum (13 % Rhodium)
    Black
    Orange
    Platinum
    -50-1760
    B
    Platinum (30 % Rhodium)
    Gray
    Platinum (6 % Rhodium)
    200-1800
    K
    Chromel
    Yellow
    Green
    Alumel
    -200-1370
    N
    Ni-Cr-Si
    Orange
    Pink
    Ni-Si-Mg
    -200-1300
    E
    Chromel
    Purple
    Violet
    Constantan
    -200-1000
    J
    Iron
    White
    Black
    Constantan
    -200-1200
    T
    Copper
    Copper
    Brown
    Constantan
    -200-400
    *American National Standards Institute (ANSI) device negative lead (L) is always red.
    **International Electrotechnical Commission (IEC) device negative lead (L) is always white.
    RTD specification.
    RTD Type
    Ice Point (R0)
    Material
    α
    Range (°C)
    Pt100 (3926)
    100Ω
    Platinum
    0.003926Ω/ ºC
    -200 to 630
    Pt100 (3916)
    100Ω
    Platinum
    0.003916Ω/ ºC
    -200 to 630
    Pt100 (385)
    100Ω
    Platinum
    0.00385Ω/ ºC
    -200 to 800
    Pt200 (385)
    200Ω
    Platinum
    0.00385Ω/ ºC
    -200 to 630
    Pt500 (385)
    500Ω
    Platinum
    0.00385Ω/ ºC
    -200 to 630
    Pt1000 (385)
    1000Ω
    Platinum
    0.00385Ω/ ºC
    -200 to 630
    Cu100
    100Ω
    Copper (Cu)
    0.00425~0.00428Ω/ ºC
    -50  to 150
    Cu50
    50Ω
    Copper (Cu)
    -50  to 150
    Notice: According to international shipping requirements, it is forbidden to have powder, liquid, nor battery in package,In order to avoid delay of transportation, we will have to check and take out these items before packing.
    Delivery details:
    1. We are not responsible for undeliverable address. We reserve the right to charge the shipping fee again for returned items due to wrong address.
    2. Items are generally shipped within 10 business day after your payment has been cleared (Sat. & Sun. excluded.).
    Terms of sales :
    1. We offer 60 days money back guarantee return policy.
    2. Our warranty does not extended to any products that are physically damaged or that are not under normal operating conditions as a result of misuse or improper installation on the buyer/user's part.
    3. For all returned products, buyers please contact us for the returning address.
    4. In all cases, buyers pay shipping fees at their own cost to return products for exchange or refund. We will be responsible for the postage of replacements. Refund will be made upon receipt of the returned item.
    payment :
    1. All payments must be prepaid.
    2. We only accept payment via Paypal. Please kindly check if you can do the payment via PayPal before placing an order.
    Feedback:
    If you are dissatisfied for any reason, please donot be quick to leave negative/neutral feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED
    TAX &DUTY &VAT :
    The transaction does not include any Import Tax / Duty / VAT / Brokerage Fees / Handling Fees. For more information about the tax rate, please check with local custom department before purchases. If you reject the package due to any charged tax or duty, we reserve the right to charge ALL shipping cost and 5% (of total price) handling fee. Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. We do not responsible for any custom duty or import tax. Please check with your country's customs office to determine what these additional costs will be prior to bidding / buying. Sometime customs will inspect the parcel and sometime will not. If you have any special request, please kindly advise us once place order.
    Contact us:
    Please contact us with any comments, questions or suggestions that you may have bysending ebay message, All the mail will be replied within 24 hours. Please ensure your mail box would not blocked / filtered our mails.we will be happy to assist you. please feel free to contact us for WHOLESALES deal,we will surely give you a satisfatory price. We would try our best to serve you with any question / problem. Please contact us first before leaving Negative / Neutral Feedback or open any cases. We work 6 Days a week From 9:00am - 6:00pm Monday - Saturday CHINA Time.
    Best
    Customer Service
    Prompt
    Delivery
    100% Money Back
    Guarantee
    Easy & Secure
    Payments
    Copyright 2018 Complicit Components. All rights reserved.